Vocal biomarkers

Mean pause

Mean length of pauses of 250 ms or more.

Key
meanPauseS
Unit
s
RDoC domain
Sensorimotor systems
For the sample
0.535 s

Method

Mean of the silent runs counted for the pause ratio.

Quality gate

At least one pause. Below the gate the value is null and the reason is listed in the response's quality flags.

How the engine reads it

In Sensorimotor systems, with higher values than the person's own baseline read as concern, at full weight. Pauses lengthen with severity.

Published associations

ConditionIn the conditionEvidence
Depression↑higherreplicatedYamamoto M, Takamiya A, Sawada K, et al; Alpert M, Pouget ER, Silva RR
Schizophrenia spectrum↑highermeta-analysisParola A, Simonsen A, Bliksted V, et al; Cohen AS, Mitchell KR, Elvevåg B

Group-level findings from the literature, never a diagnosis. Compare a person with themselves over time.

References

  1. 1.Yamamoto M, Takamiya A, Sawada K, et al. Using speech recognition technology to investigate the association between timing-related speech features and depression severity. PLoS One 2020;15(9):e0238726. doi.org/10.1371/journal.pone.0238726
  2. 2.Alpert M, Pouget ER, Silva RR. Reflections of depression in acoustic measures of the patient's speech. J Affect Disord 2001;66(1):59-69. doi.org/10.1016/S0165-0327(00)00335-9
  3. 3.Parola A, Simonsen A, Bliksted V, et al. Voice patterns in schizophrenia: A systematic review and Bayesian meta-analysis. Schizophr Res 2020;216:24-40. doi.org/10.1016/j.schres.2019.11.031
  4. 4.Cohen AS, Mitchell KR, Elvevåg B. What do we really know about blunted vocal affect and alogia? A meta-analysis of objective assessments. Schizophr Res 2014;159(2-3):533-538. doi.org/10.1016/j.schres.2014.09.013

Measure it on your own data.